Product Details:
Payment & Shipping Terms:
|
Name: | 12kV Composite Polymer Insulator | To Be Used In: | Overhead Transmission Lines And Substations |
---|---|---|---|
Insulator Color: | Grey Or Red | Usually Packed In: | Paper Tubes Cartons Or Wooden Boxes |
Products Standards: | IEC 61109/ANSI | Insulator Model: | FXBW-12/70-WT-A To FXBW-12/70-PT-A |
Insulator Material: | Composite/polymer | Relevant Tests: | All Type Tested |
High Light: | silicone composite insulators,composite polymeric insulators |
Small 12 kV Distribution Composite Polymer Insulator Creepage Distance 400mm
Specifications:
Dimensions and Characteristics of 12kV composite polymer insulator
Figure. No | Model | Rated Voltage | Specified Mechanical Load | Coupling Size | Section Length | Insulating length | Minimum Creepage | Full-Wave Impulse Withstand Voltage (Peak) | 1 Min Wet Power Frequency Withstand Voltage | Weight (for Reference) |
kV |
kN | H mm | h mm | L mm | ≥ kV | ≥ kV |
kg | |||
1.15-1 | FXBW-12/70-WT-A | 12 | 70 | 16 | 340±5 | 163 | 400 | 95 | 60 | 1.5 |
1.15-2 | FXBW-12/70-DT-A | 12 | 70 | 16 | 343±5 | 163 | 400 | 95 | 60 | 1.3 |
1.15-3 | FXBW-12/70-WD | 12 | 70 | 16 | 322±5 | 159 | 415 | 95 | 60 | 1.3 |
1.15-4 | FXBW-12/70-DT-B | 12 | 70 | 16 | 312±5 | 159 | 415 | 95 | 60 | 1.1 |
1.15-5 | FXBW-12/70-WT-B | 12 | 70 | 16 | 319±5 | 159 | 415 | 95 | 60 | 1.2 |
1.15-6 | FXBW-12/70-UD-A | 12 | 70 | / | 318±5 | 159 | 415 | 95 | 60 | 1.2 |
1.15-7 | FXBW-12/70-UD-B | 12 | 70 | / | 360±5 | 158 | 600 | 95 | 60 | 1.4 |
1.15-8 | FXBW-12/70-UD-C | 12 | 70 | / | 365±5 | 163 | 400 | 95 | 60 | 1.4 |
Description:
1, 12kV composite polymer insulator are widely used in overhead transmission lines and substations
2, Dead end fittings are up to the requirements from the clients, usually we use ball, socket, tongue, clevis for tension insulators with forged steel or cast steel. The dimensions and coupling size can be exactly according to the specification requirements from the utilities.
3, The silicon rubber color of the insulators are also up to the requirements from the clients and all the silicon rubber materials past 5000 hours aging test silicon content test and hydrophobicity test.
4, ECR core rods are used in all the insulators, so we can guarantee a very good mechanical strength and anti-acid pollution performance for the insulators.
5, All our insulators were type tested and design tested in accordance with IEC61109, maximum RIV is 100µV when tested at 1MHz and10% over nominal line ground voltage for indicated system voltage.
6, All the 12kV tension suspension insulators are without corona ring
Applications:
1, 12kV overhead transmission power lines.
2, 12kV substations
3, 12kV distribution lines
Competitive Advantages: